  Datasheet File OCR Text:
  _______________general description the max366 and max367 are multiple, two-terminal circuit protectors. placed in series with signal lines, each two-ter- minal device guards sensitive circuit components against voltages near and beyond the normal supply voltages. these devices are used at interfaces where sensitive cir- cuits are connected to the external world and could encounter damaging voltages (up to 35v beyond the sup- ply rails) during power-up, power-down, or fault conditions. the max366 contains three independent protectors and the max367 contains eight. they can protect analog sig- nals using either unipolar (4.5v to 36v) or bipolar (2.25v to ?8v) power supplies. each protector is symmetrical. input and output terminals may be freely interchanged. these devices are voltage-sensitive mosfet transistor arrays that are normally on when power is applied and normally open circuit when power is off. with ?0v sup- plies, on-resistance is 100 max and leakage is less than 1na at +25?. when signal voltages exceed or are within approximately 1.5v of either power-supply voltage (including when power is off), the two-terminal resistance increases dra- matically, limiting fault current as well as output voltage to sensitive circuits. the protected side of the switch main- tains the correct polarity and clamps approximately 1.5v below the supply rail. there are no ?litches?or polarity reversals going into or coming out of a fault condition. ________________________applications process control systems redundant/backup systems hot-insertion boards/systems ate equipment data-acquisition systems sensitive instruments ____________________________features ? ?0v overvoltage protection ? open signal paths with power off 100 signal paths with power on ? 1na max path leakage at +25? ? 44v maximum supply voltage rating ? automatic protection; no programming or controls ______________ordering information max366/max367 signal-line circuit protectors ________________________________________________________________ maxim integrated products 1 max366 out1 sensitive amplifier 1 fault! fault! in1 (short) (open) remote sensor electronics 7 +28v +12v out2 2 in2 6 out3 3 in3 5 v+ 4 v- protector +10v reg. 8 ___________________________________________________typical operating circuit call toll free 1-800-998-8800 for free samples or literature. 19-0326; rev 0; 12/94 part ? max366 cpa max366csa max366c/d 0? to +70? 0? to +70? 0? to +70? temp. range pin-package 8 plastic dip 8 so dice* max366epa max366esa max366mja -55? to +125? -40? to +85? -40? to +85? 8 plastic dip 8 so 8 cerdip** max367 cpn max367cwn max367c/d 0? to +70? 0? to +70? 0? to +70? 18 plastic dip 18 wide so dice* max367epn max367ewn max367mjn -55? to +125? -40? to +85? -40? to +85? 18 plastic dip 18 wide so 18 cerdip** pin configurations appear at end of data sheet. ? max367 available after january 1, 1995. * dice are tested at t a = +25? only. * contact factory for availability.
max366/max367 signal-line circuit protectors 2 _______________________________________________________________________________________ absolute maximum ratings electrical characteristics (v+ = +15v, v- = -15v, t a = t min to t max , unless otherwise noted.) stresses beyond those listed under ?bsolute maximum ratings?may cause permanent damage to the device. these are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. exposure to absolute maximum rating conditions for extended periods may affect device reliability. note 1: guaranteed, but not tested. note 2: see typical operating characteristics curves for fault-free analog signal range at various supply voltages. v+ to v-......................................................................-0.3v, +44v in_, out_ ..................................................(v- + 44v), (v+ - 44v) continuous current into any terminal..............................?0ma peak current into any terminal (pulsed at 1ms, 10% duty cycle)...................................?0ma continuous power dissipation (t a = +70?) 8-pin plastic dip (derate 9.09mw/? above +70?) ....727mw 8-pin so (derate 5.88mw/? above +70?).................471mw 8-pin cerdip (derate 8.00mw/? above +70?).........640mw 18-pin plastic dip (derate 11.11mw/? above +70?) ... 889mw 18-pin wide so (derate 9.52mw/? above +70?) .....762mw 18-pin cerdip (derate 10.53mw/? above +70?).....842mw operating temperature ranges max36_c_ _ ........................................................0? to +70? max36_e_ _......................................................-40? to +85? max36_m_ _ ...................................................-55? to +125? storage temperature range .............................-65? to +150? lead temperature (soldering, 10sec) .............................+300? v+ = v- = 0v, v out = 0v, v in = ?5v v+ = 15v, v- = -15v (note 2) (note 1) v+ = 10v, v- = -10v, v in = ?v, i out = 1ma v in = ?0v, i out = 1ma v in = v+ or v-, 100k < r out < 1000m (note 1) v+ = 15v, v- = -15v, v in = ?0v, i out = 1ma v+ = 5v, v- = -5v, v in = ?v, i out = 1ma conditions na -10 10 i in(off) signal-path leakage (with overvoltage) 10 ? r (in-out) signal-path resistance match 7 400 r (in-out) analog-signal-path resistance v -11 11 v in , v out v (v+ - 40) (v- + 40) v in , v out analog signal range fault-free analog signal range 140 350 150 125 62 100 v (v- + 3) (v+ - 1.5) v out analog-signal output range (fault) 62 85 100 125 units min typ max symbol parameter +25? all all +25? m c, e, m c, e +25? all +25? c, e +25? m c, e, m temp. range v+ = v- = 0v, v in = ?5v, v out = open circuit na -1000 1000 i in(off) signal-path leakage (power off) -10 10 c, e, m +25? v in = ?5v, v out = open circuit na -1000 1000 i in(on) signal-path leakage (with fault condition) -10 10 c, e, m +25? v in = v out = ?0v na -100 100 i out(on) signal-path leakage (without fault condition) -1 1 c, e, m +25? -1 1 +25? r (in-out) < 1000 (note 2) v ?.25 ?8 v+, v- power-supply range (without fault condition) +25?, c, e, m ? -10 10 i+, i- power-supply current c, e, m v 0 ?8 v+, v- power-supply range +25?, c, e, m c, e, m -1000 1000 power supply
max366/max367 signal-line circuit protectors _______________________________________________________________________________________ 3 -25 -35 15 25 35 transfer characteristics (bipolar supplies) max366/7-02 input voltage (v) output voltage (v), input & output current ( m a) 0 -15 -5 5 -15 15 0 -10 -5 10 5 v+ = +3v, v- = -3v v+ = +5v, v- = -5v v+ = +15v, v- = -15v v+ = +15v, v- = -15v v+ = +10v, v- = -10v v+ = +10v, v- = -10v output load = 1m w 15 25 35 20 30 transfer characteristics (single supply) max366/7-03 input voltage (v) v in > (v+ - 35v) output voltage (v), input & output current ( m a) 0 10 5 15 0 10 25 20 5 v+ = 25v v+ = 15v v+ = 10v v+ = 5v output load = 1m w v- = 0v 1e+01 1e+02 1e+03 1e+04 1e+05 1e+06 1e+07 1e+08 -15 15 path resistance vs. input voltage (bipolar supplies) max366/7-04 input voltage (v) path resistance ( w ) 0 -10 -5 10 5 v?= ?5v circuit of fig. 6 v?= ?0v v?= ?v v?= ?v 500 0 -15 15 path resistance vs. input voltage (bipolar supplies) 400 max366/7-05 input voltage (v) path resistance ( w ) 0 200 100 -10 -5 10 300 50 450 250 150 350 5 v?= ?5v v?= ?0v v?= ?v v = ?v circuit of fig. 6 __________________________________________typical operating characteristics (v+ = +15v, v- = -15v, t a = +25?, unless otherwise noted.)
max366/max367 signal-line circuit protectors 4 _______________________________________________________________________________________ ____________________________typical operating characteristics (continued) (v+ = +15v, v- = -15v, t a = +25?, unless otherwise noted.) v+ = 5v, v- = -5v chan 1: input overvoltage ramp ?v, 2v/div chan 2: output; output load = 1000 w , 2v/div overvoltage ramp -12 10 max366 frequency response max366-toc9 frequency (hz) loss (db) -10 -8 -6 -4 -2 0 1k 10k 100k 1m 10m 100m 100 source = 50 w load = 50 w v+ = 5v v- = -5v 100 path resistance vs. input voltage (single supply) max366/7-06 input voltage (v) path resistance ( w ) 10 1 v+ = 35v v+ = 25v v+ = 15v v+ = 10v v+ = 5v v- = 0v 10 100 1k 10k 100k 1m 10m 1g 100m circuit of fig. 6 500 0 100 path resistance vs. input voltage (single supply) 400 max366/7-07 input voltage (v) path resistance ( w ) 200 100 10 1 300 50 450 250 150 350 v+ = 35v v+ = 25v v+ = 15v v+ = 10v v+ = 5v v- = 0v circuit of fig. 6
max366/max367 signal-line circuit protectors _______________________________________________________________________________________ 5 ___________background information when a voltage outside the supply range is applied to most integrated circuits, there is a strong possibility they will be damaged or ?atch up?(that is, fail to operate prop- erly even after the offending voltage is removed). if an ic? input or output pin is supplied with a voltage when the ic? power is off, and power is subsequently applied, the device may act as an scr and destroy itself and/or other circuitry. such ?aults?are commonly encountered in modular control systems where power and signals to inter- connected modules may be interrupted and re-estab- lished at random. they can happen during production testing, maintenance, start-up, or a power ?rownout. the max366/max367 are designed to protect delicate input and output circuitry from overvoltage faults up to ?0v (with or without power applied), in devices such as op amps, analog-to-digital/digital-to-analog converters, and voltage references. these circuit protectors automati- cally limit signal voltages and currents to safe levels with- out degrading normal signal performance, even in very high-impedance circuits. they are powered by the power supply of the protected circuit and inserted into the signal lines. there are no control lines, programming pins, or adjustments. unlike shunt diode networks, these devices are low- impedance fets that become high impedance during a fault condition, so fault current and power dissipation are extremely low. equally important, leakage current during normal and fault conditions is extremely low. in addition, unlike most discrete networks, these parts protect circuits both when power is off and during power transitions. _______________detailed description internal construction figure 1 shows the simplified internal construction of each protector inside the max366/max367. each circuit consists of two n-channel fets and one p-channel fet. all the fets are enhancement types; that is, the n chan- nels must have approximately 1.3v of positive gate volt- age in order to conduct, and the p channel must have approximately 2v of negative gate voltage in order to conduct. during normal operation, v+ is connected to a positive potential and v- is connected to a negative potential. since their gates are tied to v+, transistors q1 and q3 conduct as long as their sources are at least 1.3v below v+ (the n-channel gate threshold.) transistor q2? gate is tied to v-, so it conducts as long as its source is 2v or more above v- (the p-channel gate threshold.) ______________________________________________________________pin description pin max366 max367 function 1, 2, 3 1, 2, 3 signal inputs 1, 2, 3 4? signal inputs 4? 4 9 negative supply voltage input name* in1, in2, in3 8 18 positive supply voltage input 10?4 signal outputs 4? in4?n8 v- v+ out8?ut4 5, 6, 7 15, 16, 17 signal outputs 1, 2, 3 out3, out2, out1 * inputs and outputs are names for convenience only; inputs and outputs are identical and interchangeable. p q2 n q3 n q1 out v+ v- in figure 1. simplified internal structure
as long as the signal is within these limits, all three tran- sistors conduct and a low-resistance path is maintained from the in to out pin. (note that, since the device is symmetrical, in and out pins can be interchanged.) when the signal is beyond the gate threshold of either q2 or q1/q3, the path resistance rises dramatically. when power is off, none of the transistors have gate bias, so the circuit from in to out is open. normal operation in normal operation, the protector is placed in series with the signal line and the power supplies are con- nected to v+ and v- (see figure 2). v- is ground when operating with a single supply. when power is applied, each protector acts as a resistor in the signal path. any voltage source on the ?nput?side of the switch will be conducted through the protector to the output. (note that, since the protector is symmetrical, in and out pins can be interchanged.) if the output load is resistive, it will draw current, and a voltage divider will be formed with the internal resistance so the output voltage will be lower than the input voltage. since the internal resistance is typically less than 100 , high-impedance loads will be relatively unaffected by the presence of the protector. the protector? path resis- tance is a function of the supply voltage and the signal voltage (see typical operating characteristics ). power off when power is off (i.e., v+ = v- = 0v), the protector is a virtual open circuit, and all voltages on each side are isolated from each other up to ?0v. with ?0v applied to the input pin, the output pin will be 0v, regardless of its resistance to ground. fault conditions a fault condition exists when the voltage on either sig- nal pin is within about 1.5v of either supply rail or exceeds either supply rail. this definition is valid when power is applied and when it is off, as well as during all the states as power ramps up or down. during a fault, the protector acts as a variable resistor, conducting only enough to sustain the other side of the switch within about 1.5v of the supply rail. this voltage is known as the ?ault knee voltage,?and is not symmet- rical. it is approximately 1.3v down from the positive supply (v+ pin) or approximately 2.0v up from the neg- ative supply (v- pin). each fault knee voltage varies slightly with supply voltage, with output current, and from device to device. during a fault condition, all the fault current flows from one signal pin through the protector and out the other signal pin. no fault current flows through either supply pin. (there will be a few pico-amps of leakage current from each signal pin to each supply pin, but this is independent of fault current.) during the fault condition, enough current will flow to maintain the output voltage at the fault knee voltage, so the fault current is a function of the output resistance and the supply voltage. the output voltage and cur- rent have the same polarity as the fault. the maximum input fault voltage is 40v from the ?ppo- site-polarity supply rail.? this means the input can go to ?5v with ?v supplies or to ?5v with ?5v sup- plies. the fault voltage is highest (?0v) when the sup- plies are off (v+ = v- = 0v). using the circuit of figure 2, the approximate fault cur- rents are as follows: 1) for positive faults: i (f) (v+ - 1.3v - v low ) r out 2) for negative faults: i (f) (v- + 2v + v low ) r out where v low is the terminating voltage at the far end of r out . v low = 0v when r out is grounded. max366 out1 1 4 in1 7 v+ v- v+ v- 8 v out v in r out v low figure 2. application circuit max366/max367 signal-line circuit protectors 6 _______________________________________________________________________________________
max366/max367 signal-line circuit protectors _______________________________________________________________________________________ 7 the current through each protector should never exceed 30ma. always calculate the power dissipated by all the protectors in worst-case conditions (maximum voltage and current through each protector) to ensure the pack- age dissipation limit is not reached. with single-supply operation, grounded loads will have zero voltage (and current) whenever the input voltage is below approximately 2v. in effect, both the in and out pins are in fault condition. a special case arises when power is off: the part is in a perpetual fault condition but no fault current flows because all the internal fets are off. single-supply output operation single-supply operation is a special case. signals can- not go to ground, since from 0v to approximately +2v is a fault condition. extremely low-current operation figure 3 shows the typical high-impedance transfer characteristics with a 100m load. compared to the transfer characteristic at 1m (see typical operating characteristics ), the two knees are closer to the supply voltages and the slopes of the flat portions of the curve (fault conditions) are steeper. as the load resistance is increased even further, the positive and negative knees increase, and the slopes in fault conditions increase even more. eventually, at some extremely high output resistance (e.g., tera ohms), the output voltage can exceed the supply voltage during fault conditions. this is due to extremely low leakage currents from the input to output. when the protector? output side is connected to very high-resistance, very low-current loads (such as op- amp inputs), a small leakage current flows from the input to the output during fault conditions. this current is typically below a nano-ampere (<10 -9 a) but, if the output resistance is high enough, it can cause the out- put voltage to exceed the supply voltages during fault conditions. this condition can be self-correcting, however, if the high-resistance load has protection diodes to the sup- ply rails (either external or internal to the op amp). these diodes conduct the leakage current to the supply rails and safely limit the output voltage. an alternative is to add a high-value resistor to ground in parallel with the load. this resistor may be as low as 1000m ; its value must be determined experimentally at the highest anticipated operational temperature. the fault protectors will not normally be used with high- impedance fet-input amplifiers that lack input protection diodes. such amplifiers are fragile and are normally reserved for use when ultra-low leakage (pa) is needed. the max366/max367 have nano-amperes of leakage, which would negate the low leakage of the unprotected amplifier. low-voltage operation the max366/max367 ?perate?with supply voltages all the way down to 0v, but what they do to the signal is not obvious. with a total supply voltage of 3.5v, the protector is in a fault condition with nearly any input that is not close to 2.0v. below 3.5v (including power off), the protector is perpetually in a fault condition (i.e., high impedance). when the supply voltage(s) ramps up (and/or down) from zero, the signal path is initially in a fault condition (open), until the supply voltage passes the input volt- age. the output starts at zero and is delayed from reaching the input voltage as the part comes out of the fault condition. if the supply voltage exceeds about 3.5v, but never exceeds the input voltage, the output will follow the supply, always remaining about 1.3v below the positive supply voltage or 2v above the neg- ative supply voltage. if the input voltage subsequently comes out of the fault condition, the output returns to the input value. this set of conditions is exactly reversed when power ramps down to zero. since the input and output pins are identical and inter- changeable, predicting whether or not the part is in a fault condition is easy: if either in or out exceeds v+ or v-, a fault condition exists and the current that flows will be just enough to cause the other signal pin (out or in) to approach the appropriate supply rail. 0 1 2 3 4 5 -1 -2 -3 -4 -30 30 max366/7-fig03 input voltage (v) output voltage (v) 0 -20 -10 20 10 v+ = +5v v- = -5v r out = 100m w figure 3. high-impedance transfer characteristic
max366/max367 signal-line circuit protectors 8 _______________________________________________________________________________________ bipolar faults the max366/max367 v+ and v- pins are normally con- nected to a circuit? most positive and most negative power supplies. when a circuit has multiple power supplies (such as ?v and ?2v) and the max366/ max367 v+ and v- pins are connected to the lower supply, it is possible to have fault conditions on both sides of the signal path at once, if both sides of the switch have paths to higher voltages. if the polarity of these faults is the same, the signal path will be open and there is no conflict. if the in and out pins are driven in opposite polarities from low-impedance sources, the lower of the two impedances will overcome the higher impedance, just as if the protector were not present. (make sure the current does not exceed the 30ma absolute maximum rating.) as the lower impedance source approaches and exceeds the fault knee voltage, the protector will conduct enough current to maintain the other signal pin near the fault knee voltage. this means when the fault knee voltage is reached, the current through the pro- tector shifts from the higher current capability of the lower impedance source to the lower current capability of the higher impedance source. _______________typical applications driven switches the max366/max367 have low supply currents (<1?), which allows the supply pins to be driven directly by other active circuitry, instead of connected directly to the power sources. in this configuration, the parts can be used as driven fault-protected switches with v+ or v- pins used as the control pins. for example, if the v- pin is grounded, you can turn the v+ pin on and off by driving it with the output of a cmos gate. this effectively connects and discon- nects three or eight separate signal lines at once. (if bipolar signals or signals that go to ground are being switched, the v- pin must be driven simultaneously to a negative potential.) always ensure that the driving source(s) does not drive the v+ pin more negative than the v- pin. figure 4 shows a simple turn-on delay that takes advantage of the max366? low power consumption. the two rc networks cause gradual application of power to the max366, which in turn applies the input signals smoothly after the amplifier has stabilized. the two diodes discharge the two capacitors rapidly when power is turned off. this circuit can be tailored to nearly any rate of turn- on by selecting the rc time constants in the v+ and v- pins, without affecting the time constant of the measuring circuit. protectors as circuit elements any of the individual protectors in a max366 or max367 may be used as a switched resistor, independent of the functions of other elements in the same package. for example, figure 5 shows a max366 with two of the pro- tectors used to protect the input of an op amp, and the third element used to sequence a power supply. combining the circuits of figures 4 and 5 produces a delayed action on the switched +5v, as well as smooth application of signals to the amplifier input. _________testing circuit protectors measuring path resistance measuring path resistance requires special techniques, since path resistance varies dramatically with the in and out voltages relative to the supply voltages. conventional ohmmeters should not be used, for two reasons: 1) the applied voltage and currents are usual- ly not predictable, and 2) the true resistance is a func- tion of the applied voltage, which is dramatically altered by the ohmmeter itself. autoranging ohmmeters are particularly unreliable. max366 out1 1 10 m f 10 m f in1 7 +5v -5v op amp out2 2 in2 6 out3 3 in3 5 v+ 4 v- 8 100k 100k figure 4. turn-on delay
max366/max367 signal-line circuit protectors _______________________________________________________________________________________ 9 figure 6 shows a circuit that can give reliable results. this circuit uses a 100mv voltage source and a low- voltage-drop ammeter as the measuring circuit, and an adjustable supply to sweep the analog voltage across its whole range. the ammeter must have a voltage drop of less than one millivolt (at any current) for accu- rate results. (a keithley model 617 electrometer has a suitable ammeter circuit, appropriate ranges, and a built-in voltage source designed for this type of mea- surement.) measurements are made by setting the analog voltage, measuring the current, and calculating the path resistance. the procedure is repeated at each analog voltage and supply voltage. it is important to use a voltage source of 100mv or less. as shown in figure 4, this voltage is added to the v in voltage to form the v out voltage. using a higher volt- age could cause the out pin to go into a fault condi- tion prematurely. high-frequency performance in 50 systems, signal response is reasonably flat up to several megahertz (see typical operating characteristics ). above 5mhz, the response has sev- eral minor peaks, which are highly layout dependent. because the path resistance is dependent on the sup- ply voltage and signal amplitude, the impedance is not controlled. adjacent channel attenuation up to 5mhz is about 3db above that of a bare ic socket, and is due entirely to capacitive coupling. pulse response is reasonable, but because the imped- ance changes rapidly, fast rise times may induce ringing as the signal approaches the fault voltage. at very high amplitudes (such as noise spikes), the capacitive cou- pling across the signal pins will transfer considerable energy, despite the fact that the dc path is a virtual open circuit. max366 out_ v in 4 in_ v out v+ v- v+ v- path resistance = 100mv/a 100mv adjustable analog voltage 8 a figure 6. path-resistance measuring circuit max366 out1 1 in1 7 +5v -5v out2 2 in2 6 out3 3 in3 5 v+ 4 v- 8 p 100k switched +5v op amp figure 5. power-supply sequencing
___________________chip topography _________________pin configurations v+ in3 v- 0.112" (2.84mm) 0.085" (2.16mm) out1 out2 out3 in2 in1 transistor count: 21 substrate connected to v+ in4 in3 in2 in1 in7 in6 in5 18 17 16 15 14 13 12 11 1 2 3 4 5 6 7 8 v+ out1 out2 out3 dip/so out4 out5 out6 out7 in8 10 9 out8 v- max367 v- in3 in2 in1 8 7 6 5 1 2 3 4 v+ out1 out2 out3 top view dip/so max366 max366/max367 signal-line circuit protectors 10 ______________________________________________________________________________________ __high-voltage surge suppression these devices are not high-voltage arresters, nor are they substitutes for surge suppressers. in systems that use these forms of protection, however, the max366/max367 can fill a vital gap. figure 7 shows a typical circuit. although the surge suppressers are extremely fast shunt elements, they have very soft current knees. their clamp voltage must be chosen well above the normal signal levels, because they have excessive leakage currents as the knee is approached. this current can interfere with normal operation when signal levels are low or imped- ances are high. if the clamp voltage is too high, however, the input can be damaged. using a max366/max367 after the surge suppresser allows the surge-suppresser voltage to be set above the supply voltage (but within the overvoltage limits), dramatically reducing the effects of leakage (figure 7). during a surge, the surge suppresser clamps the input voltage to roughly ?0v. this protects the max366/max367, but the max366/max367 still dis- connect the signal from the op amp well within the ?v supply. max366 out1 1 in1 7 +5v -5v surge suppressers (+10v) out2 2 in2 6 out3 3 in3 5 v+ 4 v- 8 op amp figure 7. surge-suppression circuit
max366/max367 signal-line circuit protectors ______________________________________________________________________________________ 11 ________________________________________________________package information dim a a1 a2 a3 b b1 c d1 e e1 e ea eb l min ? 0.015 0.125 0.055 0.016 0.045 0.008 0.005 0.300 0.240 0.100 0.300 ? 0.115 max 0.200 ? 0.175 0.080 0.022 0.065 0.012 0.080 0.325 0.310 ? ? 0.400 0.150 min ? 0.38 3.18 1.40 0.41 1.14 0.20 0.13 7.62 6.10 2.54 7.62 ? 2.92 max 5.08 ? 4.45 2.03 0.56 1.65 0.30 2.03 8.26 7.87 ? ? 10.16 3.81 inches millimeters plastic dip plastic dual-in-line package (0.300 in.) dim d d d d d d min 0.348 0.735 0.745 0.885 1.015 1.14 max 0.390 0.765 0.765 0.915 1.045 1.265 min 8.84 18.67 18.92 22.48 25.78 28.96 max 9.91 19.43 19.43 23.24 26.54 32.13 inches millimeters pins 8 14 16 18 20 24 c a a2 e1 d e ea eb a3 b1 b 0?- 15 a1 l d1 e dim a a1 b c e e h l min 0.053 0.004 0.014 0.007 0.150 0.228 0.016 max 0.069 0.010 0.019 0.010 0.157 0.244 0.050 min 1.35 0.10 0.35 0.19 3.80 5.80 0.40 max 1.75 0.25 0.49 0.25 4.00 6.20 1.27 inches millimeters 21-0041a so small outline package (0.150 in.) dim d d d min 0.189 0.337 0.386 max 0.197 0.344 0.394 min 4.80 8.55 9.80 max 5.00 8.75 10.00 inches millimeters pins 8 14 16 1.27 0.050 l 0?8 h e d e a a1 c 0.101mm 0.004in. b
maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a maxim product. no circuit patent licenses are implied. maxim reserves the right to change the circuitry and specifications without notice at any time. 12 __________________maxim integrated products, 120 san gabriel drive, sunnyvale, ca 94086 (408) 737-7600 1994 maxim integrated products printed usa is a registered trademark of maxim integrated products. max366/max367 signal-line circuit protectors ___________________________________________package information (continued) dim a a1 b c e e h l min 0.093 0.004 0.014 0.009 0.291 0.394 0.016 max 0.104 0.012 0.019 0.013 0.299 0.419 0.050 min 2.35 0.10 0.35 0.23 7.40 10.00 0.40 max 2.65 0.30 0.49 0.32 7.60 10.65 1.27 inches millimeters 21-0042a wide so small outline package (0.300 in.) dim d d d d d min 0.398 0.447 0.496 0.598 0.697 max 0.413 0.463 0.512 0.614 0.713 min 10.10 11.35 12.60 15.20 17.70 max 10.50 11.75 13.00 15.60 18.10 inches millimeters pins 16 18 20 24 28 1.27 0.050 l h e d e a a1 c 0? 8 0.101mm 0.004in. b c 0?15 a d b1 b dim a b b1 c e e1 e l l1 q s s1 min ? 0.014 0.038 0.008 0.220 0.290 0.125 0.150 0.015 ? 0.005 max 0.200 0.023 0.065 0.015 0.310 0.320 0.200 ? 0.070 0.098 min ? 0.36 0.97 0.20 5.59 7.37 3.18 3.81 0.38 ? 0.13 max 5.08 0.58 1.65 0.38 7.87 8.13 5.08 ? 1.78 2.49 2.54 0.100 q l s1 e cerdip ceramic dual-in-line package (0.300 in.) s l1 e e1 pins 8 14 16 18 20 24 dim d d d d d d min ? ? ? ? ? max 0.405 0.785 0.840 0.960 1.060 1.280 min ? ? ? ? ? max 10.29 19.94 21.34 24.38 26.92 32.51 inches millimeters inches millimeters


▲Up To Search▲   

 